【Abstract】Objective To determine the situation of interdialytic ambulatory blood pressure monitoring(ABPM) and its correlation with intradialytic blood pressure (BP) in maintenance hemodialysis (MHD) patients. Methods Fifty-one MHD patients treated in Peking University People’s Hospital from Dec. 2014 to Dec. 2017 were recruited. Their interdialytic ABPM values for 44 hours and the BP values before, during and after dialysis for 3 sessions in this week were collected. Paired sample t test was used to compare interdialytic BP values and the BP values in the dialysis day. Pearson correlation analysis was used to evaluate the correlation between interdialytic ABPM values and BP values at different stages in the dialysis day. Bland-altman difference method was used to test the consistency of the two measurement methods. Results There was a difference between interdialytic ABPM values and the BP values in the dialysis day (t=- 3.854, P<0.001). There were weak correlations of interdialytic systolic BP (SBP) with the SBP before (r=0.381, P=0.007), during (r=0.442, P=0.001) and after dialysis (r=0.374, P<0.001) in the dialysis day, in which significant relationship was present between interdialytic 44 hours SBP and the SBP during dialysis. Bland-Altman analysis showed that the 95% confidence interval for the difference between interdialytic 44 hours SBP and the SBP during dialysis was -32.42, 35.64 mmHg. Conclusion Interdialytic BP was different from the BP in the dialysis day. BP in the dialysis day cannot replace ABPM for evaluating interdialytic BP in MHD patients.