[an error occurred while processing this directive]
短篇论著

单中心血液透析聚砜膜透析器反应临床观察

  • 吴私 ,
  • 周光宇 ,
  • 李德天 ,
  • 周华
展开
  • 1中国医科大学附属盛京医院肾脏内科

收稿日期: 2020-02-10

  修回日期: 2020-03-17

  网络出版日期: 2020-05-12

Clinical observation on the reaction of polysulfone membrane dialyzer in single center hemodialysis patients

  • WU Si ,
  • ZHOU Guang-Yu ,
  • LI De-Tian ,
  • ZHOU Hua
Expand

Received date: 2020-02-10

  Revised date: 2020-03-17

  Online published: 2020-05-12

本文引用格式

吴私 , 周光宇 , 李德天 , 周华 . 单中心血液透析聚砜膜透析器反应临床观察[J]. 中国血液净化, 2020 , 19(05) : 357 -358 . DOI: 10.3969/j.issn.1671-4091.2020.05.019

参考文献

[1]John T,Peter G,Todd S,等.透析手册(第5版)[M]. 李寒,等,译. 北京:人民卫生出版社,2017,230-233. [2]Poothullil J,Shimizu A,Day RP,et al.Anaphylaxis from the product(s) of ethylene oxide gas[J].Ann Intern Med, 1975, 82(1):58-60 [3]Chen DP,Flythe JE.Dialysis-associated allergic reactions during continuous renal replacement therapy and hemodialysis: A case report[J].Hemodial Int, 2020, 24(1):E5-E9 [4]Sayeed K,Murdakes C,Spec A,et al.Anaphylactic shock at the beginning of hemodialysis[J].Semin Dial, 2016, 29:81-84 [5]Désormeaux A,Moreau ME,Lepage Y,et al.The effect of electronegativity and angiotensin-converting enzyme inhibition on the kinin-forming capacity of polyacrylonitrile dialysis membranes[J].Biomaterials, 2008, 29(9):1139-1146 [6]Saha M,Allon M.Diagnosis,Treatment,and Prevention of Hemodialysis Emergencies[J].Clin J Am Soc Nephrol, 2017, 12(2):357-369 [7]Mukaya JE,Jacobson MS,Esprit D,et al.Allergic reaction to polysulphone membrane dialyser masquerading as infection[J].BMJ Case Rep, 2015, :- [8]Konishi S,Fukunaga A,Yamashita H,et al.Eluted substances from hemodialysis membranes elicit positive skin prick tests in bioincompatible patients[J].Artif Organs, 2015, 39(4):343-351 [9]Rodríguez-Sanz A,Sánchez-Villanueva R,Domínguez-Ortega J,et al.Mechanisms Involved in Hypersensitivity Reactions to Polysulfone Hemodialysis Membranes[J]. Artif Organs, 2017, 41(11):E285-E295 [10]Shimamoto Y,Matsushita S,Yamamoto T,et al.Real-Time Measurement of Polyvinylpyrrolidone Eluted from Polysulfone Membrane Dialyzers Based on the Ultraviolet Spectrum[J].ASAIO J, 2019, 65(5):522-526 [11]Martin-Navarro J,Esteras R,Castillo E,et al.Reactions to Synthetic Membranes Dialyzers: Is there an Increase in Incidence?[J].Kidney Blood Press Res, 2019, 44(5):907-914 [12]Martín-Navarro JA,Gutiérrez-Sánchez MJ,Petkov-Stoyanov V.Hypersensitivity to synthetic hemodialysis membranes[J].Nefrologia, 2014, 34(6):807-808 [13]Sánchez-Villanueva RJ,González E,Quirce S,et al.Hypersensitivity reactions to synthetic haemodialysis membranes[J].Nefrologia, 2014, 34(4):520-525 [14]Esteras R,Martín-Navarro J,Ledesma G,et al.Incidence of Hypersensitivity Reactions During Hemodialysis[J].Kidney Blood Press Res, 2018, 43(5):1472-1478 [15]Urbani A,Sirolli V,Lupisella S,et al.Proteomic investigations on the effect of different membrane materials on blood protein adsorption during haemodialysis[J].Blood Transfus, 2012, 10(Suppl 2):s101-s112 [16]Alvarez-de Lara MA,Martín-Malo A.Hypersensitivity reactions to synthetic haemodialysis membranes an emerging issue?[J].Nefrologia, 2014, 34(6):698-702 [17]Pieroni L,Levi Mortera S,Greco V,et al.Biocompatibility assessment of haemodialysis membrane materials by proteomic investigations[J].Mol Biosyst, 2015, 11(6):1633-1643 [18]Liu S,Shi W,Liang X,et al.Cellulose triacetate dialyzer reduces platelet loss during continuous veno-venous hemofiltration[J].Blood Purif, 2010, 29(4):375-382 [19]Butani L,Calogiuri G.Hypersensitivity reactions in patients receiving hemodialysis[J].Ann Allergy Asthma Immunol, 2017, 118(6):680-684 [20]Daugirdas JT,Bernardo AA.Hemodialysis effect on platelet count and function and hemodialysis-associated thrombocytopenia[J].Kidney Int, 2012, 82(2):147-157 [21]Boer WH,Liem Y,de Beus E,et al.Acute reactions to polysulfonepolyethersulfone dialysers: literature review and management[J].Neth J Med, 2017, 75(1):4-13 [22]魏丽艳,刘莉,邹春毅,等.重症透析器首次使用综合征例报道[J].中国医药指南, 2014, 12(28):287-287
文章导航

/

[an error occurred while processing this directive]