Objective To observe the efficacy and safety of fistula cannulation using a 15G needle in maintenance hemodialysis (MHD) patients. Methods This was a prospective and self-control study. A total of 26 MHD patients with mature arteriovenous fistula and routine blood flow rate of ≥350ml/min were enrolled in this study. All patients underwent high-flux hemodialysis for 6 continuous sessions, and blood flow rate was set at 350ml/min using a 16G or a 15G puncture needle. During each session, we monitored the effective blood flow rate (EBFR), arterial pressure (AP), venous pressure (VP), transmembrane pressure (TMP), online urea clearance using an online clearance monitor (OCM), and calculated single-chamber urea solute clearance index (spKt/V) by blood sampling. We recorded the impact of 16G and 15G needles on the time of compression (TC) after needle removal, pain score of the patients, and the related adverse events in the follow-up period. Results When the pump speed was set at 350ml/min using a 15G puncture needle, EBFR [(322.63±15.41)ml/min vs. (315.36±11.42)ml/min, t=-2.776,P=0.013] and OCM-spKt/V [(1.18±0.13) vs. (1.14±0.14), t=-2.178, P=0.045] were higher than those using a 16G puncture needle; AP [(-129.61±25.71)mmHg vs. (-191.27±20.05)mmHg, t=-8.441, P<0.001] and VP [(139±11.77)mmHg vs. (167.81±10.23)mmHg, t=8.822, P<0.001]were significantly lower than those using a 16G puncture needle. The time of compression after the needle removal using a 15G needle was longer than that using a 16G needle [(60.19±23.25) min vs. (54.99±20.51)min, t=3.188, P=0.004]. There was no significant difference in score of pain [(1.56±1.29) vs. (1.93±1.6), t=1.336, P=0.200]. Conclusions When the blood flow rate was set at ≥350ml/min, the use of a 15G needle can significantly increase the real blood flow compared with that of a 16G needle, thereby improving the dialysis adequacy. There is no significant difference in score of pain, but the time of compression after needle removal was longer in patients using a 15G needle than in those using a 16G needle.
GUAN Yan-Ning
,
HU Na-Na
,
CUI Zheng
,
WANG Mei
,
LUO Li
. Fistula cannulation using a 15G needle in maintenance hemodialysis patients: the safety and efficacy [J]. Chinese Journal of Blood Purification, 2022
, 21(05)
: 381
-384
.
DOI: 10.3969/j.issn.1671-4091.2022.05.018
[1]Levy J,Brown E,Lawrence A. Oxford Handbook of Dialysis[M]. 4th Edition. New York:Oxford University Press, 2016: 71-194.
[2]马晓波,陈秋馨,陈晓农,等.Adimea系统对维持性血液透析患者透析充分性的评价[J].肾脏病与透析肾移植杂志.2020,29(5):438-442
[3]徐城,杨晓秋,刘丹彦.常用的疼痛评估方法在临床疼痛评估中的作用[J]. 中国疼痛医学杂志,2015,21(3),210-212.
[4]Maria Teresa Parisotto, Volker U. Schoder, Cristina Miriunis, et al. Cannulation technique influences arteriovenous fistula and graft survival[J]. Kidney International. 2014, 86(4):790–797.
[5]叶蔚蔚,雷文辉,毛明锋,等.维持性血液透析患者动静脉内瘘血栓形成危险因素分析[J].中华现代护理杂志,2016,22(21):3018-2023.
[6]Rosa M. Marticorena, Sandra M. Donnelly. Impact of needles in vascular access for hemodialysis[J]. J Vasc Access, 2016; 17 (Suppl 1): S32-S37.
[7]Yu Kashima , Shinji Ninomiya. Hemodialysis efficiency management from the viewpoint of blood removal pressure[J]. Therapeuitc Apheresis and Dialysis. 2020, doi: 10.1111/1744-9987.13557. Online ahead of print.
[8]Lok CE, Huber TS, Lee T, et al; National Kidney Foundation. KDOQI Clinical Practice Guideline for Vascular Access: 2019 Update[J]. Am J Kidney Dis. 2020,75(4 Suppl 2):S1-S164