Objective To investigate the value of ultrasound gel pad during the ultrasound examination of autologous arteriovenous fistula (AVF) stenosis. Methods A total of 31 patients with AVF and venous access stenosis were subjected to ultrasound examination of the blood vessels in the upper extremity. The residual diameter of stenosis was measured using different transaudient medium: ultrasound gel pad and coupant. The repeatability and correlation with brachial artery blood flow were evaluated. Results All of the 31 cases had end-to-side anastomosis of radial artery-cephalic vein fistula in wrist. The stenosis located in the venous end of the fistula in 4 cases, and located in the forearm segment of cephalic vein in 27 cases. The residual diameter at the stenosis site was 1.41±0.45 mm measured with couplant, and was 1.89±0.53 mm measured with ultrasound gel pad, the difference was statistically significant (t=-3.806, P<0.001). The inter-observer correlation coefficient (ICC) with couplant was 0.887 (95% CI: 0.761~0.946, P<0.001), and was 0.974 (95% CI: 0.948~0.988, P<0.001) with ultrasound gel pad. The brachial artery flow measured by Doppler was 381.29±159.77 ml/min. The residual diameter of stenosis measured with couplant was significantly correlated with brachial artery flow (r=0.765, P<0.001). The measurement with ultrasound gel pad was also significantly correlated with brachial artery flow (r=0.817, P<0.001). Conclusion When vascular ultrasonography was performed in patients with AVF and venous access stenosis, ultrasound gel pad can reduce the compression deformities of the veins. Ultrasonography of AVF stenosis using ultrasound gel pad has a better repeatability and a better correlation with brachial artery blood flow than those using couplant.
LUO Wei-Yuan
,
HUANG Jin-Hang
,
XIE Yan-Hua
,
LIU Pei-Jun
,
XIE Yu-Huan
. Application of ultrasound gel pad during the ultrasound examination of autologous arteriovenous fistula stenosis[J]. Chinese Journal of Blood Purification, 2023
, 22(1)
: 61
-63
.
DOI: 10.3969/j.issn.1671-4091.2023.01.014
[1]金其庄, 王玉柱, 叶朝阳,等.中国血液透析用血管通路专家共识第版[J].中国血液净化, 2019, 18(6):365-381
[2]张翠平,崔立刚,刘佩佩,等.导声垫在表浅软组织病变超声检查中的应用对比研究[J].中国超声医学杂志, 2019, 35(6):554-556
[3]刘晓娜, 郑海宁, 温朝阳.不同角度的楔形导声垫对测量颈动脉血流速度影响的临床研究[J].中风与神经疾病杂志, 2022, 39(1):8-11
[4]于航,熊颖,刘昊,等.导声垫在甲状腺剪切波弹性成像中运用的可行性初步探究[J].中国超声医学杂志, 2020, 36(6):481-484
[5]徐元恺, 甄景琴, 张文云,等.内瘘静脉最小内径可作为判断自体动静脉内瘘狭窄的指标[J].中华肾脏病杂志, 2017, 33(3):187-190
[6]段秀芳, 郑茜子, 刘瑶,等.彩色多普勒超声在血液透析患者自体动静脉内瘘血流量测量中的应用[J].中国超声医学杂志, 2020, 36(9):833-835
[7]Schwarz C, Mitterbauer C, Boczula M, et al. . 2003,42(3):539-45.[J].Am J Kidney Dis, 2003, 42(3):539-545
[8]张晗, 刘姣, 王恒进,等.超声监测肱动脉血管参数对自体动静脉内瘘并发症的诊断价值[J].中华诊断学电子杂志, 2021, 9(4):226-231
[9]Meola M, Marciello A, Di Salle G, et al.Ultrasound evaluation of access complications: Thrombosis, aneurysms, pseudoaneurysms and infections.[J].J Vasc Access, 2021, 22(1):71-83
[10]Fahrtash F, Kairaitis L, Gruenewald S, et al.Defining a significant stenosis in an autologous radio-cephalic arteriovenous fistula for hemodialysis.[J].Semin Dial, 2011, 24(2):231-238
[11]Corvino A, Sandomenico F, Corvino F, et al.Utility of a gel stand-off pad in the detection of Doppler signal on focal nodular lesions of the skin[J].Journal of Ultrasound, 2020, 23(1):45-53
[12]Kinnick RR, Katayama M, Belohlavek M.An Interposed Pad in Open-Chest Echocardiographic Porcine Scans for Mimicking Ultrasound Signal Attenuation in a Human Chest.[J]. J Ultrasound Med, 2018, 37(2):501-509