[an error occurred while processing this directive]

Analysis of radiation dose during interventional procedure for hemodialysis access

  • CHEN Zhi-Chun ,
  • WANG Ying ,
  • HU Rong-Rong ,
  • HU Yan ,
  • FAN Xiao-Hong ,
  • LIU Bing-Yan ,
  • XIA Jing-Hua
Expand
  • Department of Nephrology, Peking Union Medical Collage Hospital, Beijing 100730, China

Received date: 2022-11-01

  Revised date: 2023-01-05

  Online published: 2023-03-03

Abstract

Objective   To investigate the dose of radiation exposure during the common interventional radiologic procedures for blood access and to evaluate its risks.  Methods  Data of the adults treated with interventional radiologic procedure for hemodialysis access between December 2020 and August 2022 were retrospectively analyzed. Fluoroscopy time (T), frames (F), dose area product (DAP), and cumulative does (CD) were recorded, and peak skin dose (PSD) was calculated. Standard statistical assessments were employed for the analyses.  Results A total of 408 patients were collected, including 6 procedure types of tunneled cuffed central venous catheter placement (TCC placement) 223, arteriovenous fistula-percutaneous transluminal angioplasty (AVF-PTA) 95,arteriovenous graft-PTA(AVG-PTA)28, arteriovenous graft-thrombectomy (AVG-thrombectomy) 27, tunneled cuffed central venous catheter replacement + central vein-PTA (TCC replacement+CV-PTA) 14, and central vein-PTA(CV-PTA) 21; the median PSD was 1.43(0.60,5.28), 6.33(3.94,9.91), 6.41(2.66,13.09), 7.38 (4.23,10.86), 30.52(19.08,52.73), and 60.64(36.17,79.92) mGy respectively; the median DAP was 0.63(0.27,2.26), 4.02(2.57,6.49), 4.21(1.74,8.53), 4.27(2.72,7.13), 13.51(8.44, 29.30), and 26.84(18.02, 35.37) Gy·cm² respectively.  Conclusions   Most interventional radiologic procedures for hemodialysis access were the exposure of low or medium radiation doses. Radiation exposure doses in central venous intervention procedures were significantly higher than those in peripheral vascular intervention procedures.

Cite this article

CHEN Zhi-Chun , WANG Ying , HU Rong-Rong , HU Yan , FAN Xiao-Hong , LIU Bing-Yan , XIA Jing-Hua . Analysis of radiation dose during interventional procedure for hemodialysis access[J]. Chinese Journal of Blood Purification, 2023 , 22(03) : 210 -213 . DOI: 10.3969/j.issn.1671-4091.2023.03.012

References

[1]张翼,宋少娟,曲桂莲,刘卫东,等.10 种介入诊疗程序中患者的辐射剂量调查[J].中华放射医学与防护杂志,2011 ,31( 4) : 482-484.DOI: 10. 3760 / cma. j. issn. 0254-5098. 2011. 04. 029
[2] International Electrotechnical Commission. Report 60601. Medical electrical equipment—Part 2-43: particular requirements for the safety of X-ray equipment for interventional procedures. Geneva: IEC,2000.
[3]Mill DL,Balter S,Cole PE,et al.Radiation doses in interventional radiology procedures:The RAD-IR Study[J],PartⅡ:skin dose.J Vasc Interv Radiol,2003,14(8):977-990.
[4] ICRP. Avoidance of radiation injuries from medical interventional procedures. ICRP Publication 85. Oxford: Pergamon Press,2001.
[5]Koenig TR,Wolff D,Mettle FA,et al.Skin injuries from fluoroscopically guided procedures:part 1,characteristics of radiation injury[J].AJR Am J Roentgenol,2001,177(1):3-11.
[6]张梦龙,孙峰,杨显存,等.接受常规心脏介入放射诊疗患者的辐射剂量分析[J].中华放射学杂志,2015,49(9):670-674.DOI:10.3760/cma.j.issn.1005-1201.2015.09.007
[7]白 玫,刘 彬,郑钧正.心脏介入患者受照剂量研究[J].介入放射学杂志,2007,16(4):222-225.DOI:10.3969/j.issn.1008-794X.2007.04.003.
[8]Tsapaki V,Kottou S,Vano E,et al. Patient dose values in a dedicated Greek cardiac center[J].Br J Radiol,2003,76:26- 730.
[9]洪洋,谢晋东.医用放射防护学(第2版).人民卫生出版社,168-169