[an error occurred while processing this directive]

Progresses in the application of drug-coated balloon for hemodialysis access

  • BAO Xue-Dong ,
  • SHI Ya-Xue
Expand
  • Department of Vascular Surgery, Longhua Hospital, Shanghai University of Traditional Chinese Medicine, Shanghai 200032, China

Received date: 2023-02-13

  Revised date: 2023-05-16

  Online published: 2023-08-12

Abstract

Hemodialysis access is the lifeline of the patients with end-stage renal disease. Vascular stenosis due to intimal hyperplasia is the main cause of access dysfunction. Percutaneous balloon dilatation angioplasty is an important intervention method to solve the stenosis in access route. In recent years, paclitaxel coated balloon has been used for repair of hemodialysis access, but its clinical and social economy efficacies are often concerned by doctors due to its higher price. This article reviews the recent progresses in the application of drug-coated balloon for hemodialysis access.

Cite this article

BAO Xue-Dong , SHI Ya-Xue . Progresses in the application of drug-coated balloon for hemodialysis access[J]. Chinese Journal of Blood Purification, 2023 , 22(08) : 612 -615 . DOI: 10.3969/j.issn.1671-4091.2023.08.010

References

[1]金其庄, 王玉柱, 叶朝阳, 等.中国血液透析用血管通路专家共识(第2版)[J]. [J].中国血液净化, 2019, 18(6):365-381
[2]Roy-Chaudhury P, Sukhatme VP, Cheung AK.Hemodialysis vascular access dysfunction: a cellular and molecular viewpoint[J].J Am Soc Nephrol, 2006, 17(4):1112-1127
[3]Mima A.Hemodialysis Vascular Access Dysfunction: Molecular Mechanisms and Treatment[J].Ther Apher Dial, 2012, 16(4):321-327
[4]National Kidney Foundation.KDOQI clinical practice guideline for vascular access: 2019 update[J].Am J Kidney Dis, 2020, 75(4):1-164
[5]Huber, T. S . Stent Graft versus Balloon Angioplasty for Failing Dialysis-Access Grafts. [J].J Vasc Access, 2010, 362(6):494-503
[6]Aruny JE, Lewis CA, Cardella JF, et al.Society of Interventional Radiology Standards of Practice Committee. Quality improvement guidelines for percutaneous management of the thrombosed or dysfunctional dialysis access[J].J Vasc Interv Radiol, 1999, 10(4):491-498
[7]Kelly B S, Heffelfinger S C, Whiting J F, et al.Aggressive venous neointimal hyperplasia in a pig model of arteriovenous graft stenosis[J].Kidney Int, 2002, 62(6):2272-2280
[8]Lee T, Roy-Chaudhury P.Advances and New Frontiers in the Pathophysiology of Venous Neointimal Hyperplasia and Dialysis Access Stenosis[J].Adv Chronic Kidney Dis, 2009, 16(5):329-338
[9]Nishiyama N, Komatsu T, Kuroyanagi T, et al.Clinical value of drug-coated balloon angioplasty for de novo lesions in patients with coronary artery disease[J]. Int J Cardiol, 2016, 222(1):113-118
[10]Schiff P B, Fant J, Horwitz S B.Promotion of microtubule assembly in vitro by taxol[J].Nature, 1979, 277(5698):665-667
[11]Scheller B, Speck U, Schmitt A, et al.Addition of paclitaxel to contrast media prevents restenosis after coronary stent implantation[J].J Am Coll Cardiol, 2003, 42(8):1415-1420
[12]Lookstein R A, Haruguchi H, Ouriel K, et al.Drug-Coated Balloons for Dysfunctional Dialysis Arteriovenous Fistulas[J].N Engl J Med, 2020, 383(8):733-742
[13] Han A, Park T, Kim HJ, Min S, et al..Editor' s Choice - Paclitaxel Coated Balloon Angioplasty vs. Plain Balloon Angioplasty for Haemodialysis Arteriovenous Access Stenosis: A Systematic Review and a Time to Event Meta-Analysis of Randomised Controlled Trials.[J].Eur J Vasc Endovasc Surg., 2021, 62(4):597-609
[14]Fong KY, Zhao JJ, Tan E, et al.Drug Coated Balloons for Dysfunctional Haemodialysis Venous Access: A Patient Level Meta-Analysis of Randomised Controlled Trials. [J].Eur J Vasc Endovasc Surg., 2021, 62(4):610-621
[15] Holden A, Haruguchi H, Suemitsu K, et. IN.PACT AV Access Randomized Trial: 12-month Clinical Results Demonstrating the Sustained Treatment Effect of Drug-Coated Balloons[J].[J].J Vasc Interv Radiol, 2022, 33(8):884-894
[16]Maya I D, Oser R, Saddekni S, et al.Vascular access stenosis: Comparison of arteriovenous grafts and fistulas[J]. Am J Kidney Dis, 2004, 44(5):859-865
[17]Swedberg SH, Brown BG, Sigley R,et al.Intimal fibromuscular hyperplasia at the venous anastmosis of PTFE grafts in hemodialysis patients.Clinical, immunocytochemical, light and electron microscopic assessment[J].[J].Circulation, 1989, 80(6):1726-1736
[18]Liao MT, Lee CP, Lin TT, et al.A randomized controlled trial of drug-coated balloon angioplasty in venous anastomotic stenosis of dialysis arteriovenous grafts[J]. [J].J Vasc Surg, 2020, 71(6):1994-2003
[19]Hongsakul, Keerati, Bannangkoon, et al.Paclitaxel-Coated Balloon Angioplasty for Early Restenosis of Central Veins in Hemodialysis Patients: A Single Center Initial Experience[J].[J].Korean J Radiol, 2018, 19(3):410-416
[20]Massmann A, Fries P, Obst-Gleditsch K, et al.Paclitaxel-coated balloon angioplasty for symptomatic central vein restenosis in patients with hemodialysis fistulas[J].J Endovasc Ther, 2015, 22(1):74-79
[21] Kitrou PM, Steinke T, El Hage R, et al.Paclitaxel-Coated Balloons for the Treatment of Symptomatic Central Venous Stenosis in Vascular Access: Results From a European, Multicenter, Single-Arm Retrospective Analysis. [J].J Endovasc Ther, 2021, 28(3):442-451
[22]Bj?rkman P, Weselius EM, Kokkonen T,et al..Drug-Coated Versus Plain Balloon Angioplasty In Arteriovenous Fistulas: A Randomized, Controlled Study With 1-Year Follow-Up (The Drecorest Ii-Study). [J].Scand J Surg, 2019, 108(1):61-66
[23]Karunanithy N, Robinson E J, Ahmad F, et al.A multicenter randomized controlled trial indicates that paclitaxel-coated balloons provide no benefit during angioplasty of arteriovenous fistulas[J].Kidney Int, 2021, 100(2):447-456
[24]Liao MT, Chen MK, Hsieh MY, et al.Drug-coated balloon versus conventional balloon angioplasty of hemodialysis arteriovenous fistula or graft: A systematic review and meta-analysis of randomized controlled trials[J][J].PLoS One, 2020, 15(5):e0231463-e0231463
[25] Phang CC, Tan RY, Pang SC, et al..Paclitaxel-coated balloon in the treatment of recurrent dysfunctional arteriovenous access, real-world experience and longitudinal follow up. [J].Nephrology (Carlton), 2019, 24(12):1290-1295
[26]Tozzi M, Franchin M, Savio D, et al..Drug-coated balloon angioplasty in failing haemodialysis arteriovenous shunts: 12-month outcomes in 200 patients from the Aperto Italian registry. [J].J Vasc Access, 2019, 20(6):733-739
[27]Swedberg S H, Brown B G, Sigley R, et al.Intimal fibromuscular hyperplasia at the venous anastomosis of PTFE grafts in hemodialysis patientsClinical,immunocytochemical,light and electron microscopic assessment.[J].Circulation, 1989, 80(6):1726-1736
[28]Trerotola S O, Kwak A, Clark T, et al.Prospective study of balloon inflation pressures and other technical aspects of hemodialysis access angioplasty[J].J Vasc Interv Radiol, 2005, 16(12):1613-1618
[29]Kitrou PM, Spiliopoulos S, Katsanos K, et al.Paclitaxel-coated versus plain balloon angioplasty for dysfunctional arteriovenous fistulae: one-year results of a prospective randomized controlled trial[J].J Vasc Interv Radiol, 2015, 26(3):348-354
[30]Schorn I, Malinoff H, Anderson S, et al.The Lutonix drug-coated balloon: A novel drug delivery technology for the treatment of vascular disease[J].Adv Drug Deliv Rev, 2017, 112(5):78-87
[31]Trerotola SO, Saad TF, Roy-Chaudhury P; Lutonix AV Clinical Trial Investigators.The Lutonix AV Randomized Trial of Paclitaxel-Coated Balloons in Arteriovenous Fistula Stenosis: 2-Year Results and Subgroup Analysis.[J].J Vasc Interv Radiol, 2020, 31(1):1-14
[32]Scheller, B.Paclitaxel Balloon Coating,a Novel Method for Prevention and Therapy of Restenosis[J].Circulation, 2004, 110(7):810-814
[33]Cremers, Bodo, Speck, et al.Drug-eluting balloon: Very short-term exposure and overlapping[J].Thromb Haemost, 2009, 101(1):201-6
[34] Hehrlein C, Richardt G, Wiemer M, et al.Description of Pantera Lux paclitaxel-releasing balloon and preliminary quantitative coronary angiography (QCA) results at six months in patients with coronary in-stent restenosis.[J].Eurolntervention, 2011, 7(5):119-124
[35] Yazdani SK, Pacheco E, Nakano M, et al..Vascular, downstream, and pharmacokinetic responses to treatment with a low dose drug-coated balloon in a swine femoral artery model. [J].Catheter Cardiovasc Interv, 2014, 83(1):132-140
[36] Katsanos K, Spiliopoulos S, Kitrou P, et al.Risk of Death Following Application of Paclitaxel-Coated Balloons and Stents in the Femoropopliteal Artery of the Leg: A Systematic Review and Meta-Analysis of Randomized Controlled Trials[J].J Am Heart Assoc, 2018, 7(24):e011245-e011245
[37] Pietzsch JB, Geisler BP, Manda B, et al.. IN.PACT AV Access Trial: Economic Implications of Drug-Coated Balloon Treatment for Dysfunctional Arteriovenous Fistulas. [J].J Vasc Interv Radiol, 2022, 23(22):1051-0443