[an error occurred while processing this directive]

Cross-sectional survey of the distribution of optic nerve sheath diameter by ultrasound measurement in patients on maintenance hemodialysis

  • LUO Hui-Chang ,
  • SONG Li ,
  • YIN Yan ,
  • QUAN Zi-Lin ,
  • CUI Dong-Mei ,
  • ZHAO Li-Yan ,
  • CHEN Cheng
Expand
  • Department of Nephrology, Dongguan Tungwah Hospital, Dongguan 523110, China; 2Department of Nephrology, Guangdong Provincial People's Hospital, Southern Medical University (Guangdong Academy of Medical Sciences), Guangzhou 510080, China; 3Department of Nephrology, Peking University Shenzhen Hospital, Shenzhen 518034, China

Received date: 2023-03-20

  Revised date: 2023-08-09

  Online published: 2023-09-28

Abstract

Objectives  This is a cross-sectional survey to observe the distribution of optic nerve sheath diameter (ONSD) by ultrasound measurement in maintenance hemodialysis (MHD) patients.  Method  The MHD patients treated in the period from September to October 2022 were recruited. Ultrasound examination of both eyes was performed by one examiner. The ONSD of an eye was measured from the longitudinal and transverse eye sections 3mm after the bulb, and the two values were then averaged.  Results  A total of 206 MHD patients were enrolled, with the mean age of 60.2±14.3 years, the mean dialysis age of 62.5 (26.0~113.0) months, and 80.6% female patients (166 cases). Diabetic nephropathy was found in 71 cases (34.5%), and coronary heart disease was found in 40 cases (19.4%). The average ONSD was higher in males than in females (t=3.180, P=0.002). The average ONSD of left eyes was greater in males than in females (t=-3.399, P=0.001). The average ONSD of both eyes increased significantly in MHD patients with diabetes, as compared with those without diabetes (t=-3.824, P<0.001). In contrast, the average ONSD of both eyes had no differences between the MHD patients with and without coronary heart disease (t=-1.064, P=0.289).  Conclusion  The distribution of ONSD is closely related to gender and the diabetic nephropathy in MHD patients. Clinically, the left side ONSD is significantly higher than that of right side in male patients with diabetic nephropathy. 

Cite this article

LUO Hui-Chang , SONG Li , YIN Yan , QUAN Zi-Lin , CUI Dong-Mei , ZHAO Li-Yan , CHEN Cheng . Cross-sectional survey of the distribution of optic nerve sheath diameter by ultrasound measurement in patients on maintenance hemodialysis[J]. Chinese Journal of Blood Purification, 2023 , 22(10) : 754 -758 . DOI: 10.3969/j.issn.1671-4091.2023.10.008

References

[1] 王卉,邢海英,刘文宏,等.超声测量视神经鞘直径影响因素的研究[J].中华老年心脑血管病杂志,2018,20(10):1066-1068.
[2]LochnerP,LeoneMA,CoppoL,et al.B-mode transorbital ultrasononography for the diagnosis ofacute optic neuritis.A systematic review[J].Clin Neurophysiol,2016,127(1):803-809.
[3] 向红,亢春苗,穆靓,等.高频超声测量正常成人球后3mm处的视神经鞘直径及其相关因素[J].广西医学,2020,42(09):1065-1068.
[4] HansenHC,LagrezeW,KruegerO,etal.Dependence of the optic nerve sheath diameter on acutely applied subarachnoidal pressure-an experimental ultrasoundstudy[J].Acta Ophthalmol,2011,89(6):e528-e532.
[5] 陈艳,林相彬,陈卫挺,等.超声测量视神经鞘直径在创伤性颅脑损伤中的应用价值[J].浙江临床医学,2018,20(4):611-612,615.
[6] 胡述立,汤浩,范学朋,等.超声测量视神经鞘直径评估俯卧位通气时颅内压的变化[J].实用医学杂志,2018,34(9):1520-1523.
[7]Kamran,Munawar,Muhammad Tariq,Khan,Syed Waqar,Hussain,Aayesha,Qadeer,Zahid Siddique,Shad,Sheher,Bano,Azmat,Abdullah.Optic Nerve Sheath Diameter Correlation with Elevated Intracranial Pressure Determined via Ultrasound.[J].Cureus,2019,11(2):e4145-e4145.
[8]Mohd,Raffiz,Jafri M,Abdullah.Optic nerve sheath diameter measurement: a means of detecting raised ICP in adult traumatic and non-traumatic neurosurgical patients.[J].The American journal of emergency medicine,2017,35(1):150-153.
[9] Lisandro M,Qian Y,Stephen J B,et al.Mean value of B-mode optic nerve sheath diameter as ani ndicator of increased intracranial pressure: a systematic review and meta-analysis.[J].Theultrasound journal,2021,13(1):234-236.
[10] 罗俏聪,张龙,李艳雅.中国健康成人视神经鞘直径的超声解剖学研究[J].影像研究与医学应用,2018,2(17):46-48.
[11] Geeraerts T,Newcombe V F,Coles J P,et al.Use of T2-weighted magnetic resonance imaging of the optic nerve sheath to detect raised intracranial pressure[J].Crit Care,2008,12(5):R114-R144.
[12] Maude R R,Hossain M A,Hassan M U,et al.Transorbital sonographic evaluation of normaloptic nerve sheath diameter in healthy volunteers in Bangladesh[J].PLoS One,2013,8(12):e81013-e81013.
[13] Christoph,Schroeder,Aristeidis H,Katsanos,Daniel,Richter,Georgios,Tsivgoulis,Ralf,Gold,Christos,Krogias.Quantification of Optic Nerve and Sheath Diameter by Transorbital Sonography: A Systematic Review and Metanalysis.[J].Journal of neuroimaging : official journal of the American Society of Neuroimaging,2020,30(2):165-174
[14] 陈焕,王小亭,丁欣,等.心脏术后患者视神经鞘宽度与容量状态的相关性研究[J].中华内科杂志,2016,55(10):779-783.
[15] Lund A,Damholt M B,WiisJ,etal.Intracranial pressure during hemodialysis in patients with acute braininjury.[Z].2019:63,493-499.
[16] 于泽洋,宋晓南,李聪,等.超声测量视盘联合视神经鞘对重症高颅压患者的评估价值[J].中风与神经疾病杂志,2021,38(11):976-979.
[17] 孙爱童,冯德喜,郭丽娜,等.超声测量视神经鞘直径预测颅脑损伤患者颅内压增高可行性[J].疑难病杂志,2022,21(03):263-266.
[18] 陈常兴,洪江,刘毅.超声测量视神经鞘直径在临床中的应用进展[J].中国综合临床,2018,34(02):180-183.
[19] Blaivas M,Thedoro D,Sierzenski P R.Elevated intracranial pressure detected by bedside emergency ultrasonography of the optic nerve sheath[J].Acad Emerg Med,2003,10(4):376-381.
[20] 李臻,张旭乡,杨惠青,等.超声测量视神经鞘直径预测颅内压的影响因素研究[J].中国超声医学杂志,2018,34(11):961-964.
[21] WangL,FengL,YaoY,etal.Optimal optic nerve sheath diameter threshold for the identification of elevated opening pressure on lumbar puncture in a Chinese population[J].PLoSOne,2015,10(2):e117939-e117939.
[22] Del S P,Redondo-Gonzalez O,Mateu-MateuA,et al.Sonographic assessment of the optic nerve sheath diameter in the diagnosis of idiopathic intracranial hypertension[J].JNeurolSci,2016,361(1):122-127.
[23] Maissan I M,Dirven P J,Haitsma I K,et al.Ultrasonographic measured optic nerve sheath diameter as an accurate and quick monitor for changes in intracranial pressure[J].JNeurosurg,2015,123(3):743-747.
[24] Wang LJ,YaoY,FengLS,et al.Noninvasive and quantitative intracranial pressure estimation using ultrasonographic measurement of optic nerve sheath diameter[J].SciRep,2017,1(7):42063-42063.
[25] Soliman I,Johnson G,Gillman L M,et al.New Optic Nerve Sonography Quality Criteria in the Diagnostic Evaluation of Traumatic Brain Injury[J].Crit Care ResPract,2018,20(18):358-362.
[26] Munawar K,Khan M T,Hussain S W,et al.Optic Nerve Sheath Diameter Correlation with Elevated Intracranial Pressure Determined via Ultrasound[J].Cureus,2019,11(2):e4145-e4145.
[27] Genena K H,Ahmed S,Szerlip H M,et al.Half the V by 120:A practical approach to the prevention of the dialysis disequilibrium syndrome.[Z].2021,25(1),424-432.
[28] Fletcher J J,Bergman K,Carlson G,et al.Continuous renal replacement therapy for refractoryintracranial hypertension[J].JTRAUMA,2010,68(6):1506-1509.
[29] 王蕾,朱保锋,张毅,等.健康成年人视神经鞘直径的影响因素分析[J].广西医学,2017,39(12):1862-1864.
[30] 王丽娟,冯良枢,姚燕,等.超声评估中国健康成年人视神经鞘直径[J].中国卒中杂志,,2016,11(7):556-562
[31] Rohit P,Muhammad A B C,Sarah G,et al.Ultrasound of Optic Nerve Sheath Diameter andStroke Outcomes.[J].Critical care explorations,2021,3(11):234-236.
[32] 高孝蓉.集束化护理干预在视神经鞘B超测量监测患者颅内压中的应用[J].国际护理学杂志,2021,40(11):2043-2046.