[an error occurred while processing this directive]

Hemodynamic characteristics before and after hemodialysis and their clinical significances

  • HUANG Hong ,
  • QIU Qiang ,
  • LIU Qiang ,
  • YAN Dong-Mei
Expand
  • Department of Nephrology, Beijing Shunyi District Hospital, Beijing 101300, China

Received date: 2024-11-19

  Revised date: 2025-03-31

  Online published: 2025-06-12

Abstract

Objective  To observe the changes of hemodynamic parameters before and after hemodialysis in maintenance hemodialysis (MHD) patients, and to explore the clinical value of hemodynamic monitoring in MHD patients by comparison of clinical indicators between patients with improved and those with unimproved hemodynamics.  Methods  Patients undergoing stable MHD at the Department of Nephrology, Beijing Shunyi District Hospital were selected as study subjects. General clinical data were collected, venous blood samples were obtained before and after hemodialysis, and non-invasive hemodynamic monitoring using thoracic electrical bioimpedance was performed. Changes in hemodynamic parameters before and after dialysis and their correlations with clinical indicators were analyzed.  Results  A total of 41 patients were included.  ① Significant differences in heart rate, heart rate variability, cardiac index, thoracic fluid conductivity, pulmonary capillary wedge pressure, and systemic vascular resistance were observed before and after hemodialysis (t=0.056, 2.932, 0.998, 0.022, 0.637 and 2.653 respectively; P=0.023, 0.021, 0.015, 0.005, 0.006 and 0.030 respectively).  ② In the 27 patients with improved hemodynamic status after dialysis, mean arterial pressure, systemic vascular resistance, systolic blood pressure, and diastolic blood pressure decreased significantly post-dialysis (t=0.924, 2.136, 2.453 and 0.092 respectively; P=0.009, 0.013, 0.004 and 0.047 respectively).  ③ In the patients with improved hemodynamic status after dialysis, lower total cholesterol levels and the better control of intact parathyroid hormone (iPTH) were found, as compared those in the unimproved group (t=4.705 and 5.327; P=0.036 and 0.026).  Conclusion  Hemodynamic parameters undergo significant changes after dialysis in MHD patients. Patients demonstrating improved hemodynamic after dialysis exhibit relatively stable blood pressure profiles and better controls of total cholesterol and iPTH.

Cite this article

HUANG Hong , QIU Qiang , LIU Qiang , YAN Dong-Mei . Hemodynamic characteristics before and after hemodialysis and their clinical significances[J]. Chinese Journal of Blood Purification, 2025 , 24(06) : 452 -456 . DOI: 10.3969/j.issn.1671-4091.2025.06.003

References

1. Journal of Clinical Rehabilitative Tissue Engineering Research January 29, 2008 Vol.12, No.5.
2. 张俊霞,徐金升,周薇,等.应用无创血流动力学监测评估血液透析容量状况研究[J].中国实用内科杂志,2012,32 ( 9) : 704-706.
3. 冯晓玲,徐金升,张俊霞,等.BioZ. com无创血流动力学监测系统指导终末期肾脏病维持性血液透析患者调整超滤量价值研究[J].中国全科医学,2015,18 ( 32) : 3922-3925.
4.London GM. Alterations of arterial function in end-stage renal disease[J].Nephron 2000;84(2):111-118.
5.Amann K, Wanner C, Ritz E. Cross-talk between the kidney and the cardiovascular system[J]. J Am Soc Nephrol 2006;17:2112-2119.
6. Schiffrin EL, Lipman ML, Mann JF. Chronic kidney disease: effects on the cardiovascular system[J]. Circulation 2007;116(1):85-97.
7.Tonelli M, Wiebe N, Culleton B, et al. Chronic kidney disease and mortality risk: a systematic review[J]. J Am Soc Nephrol 2006;17:2034-2047.
8.Go AS, Chertow GM, Fan D, et al. Chronic kidney disease and the risks of death, cardiovascular events, and hospitalization[J]. N Engl J Med 2004;351:1296-1305.
9. 孟美娟,叶红,等.无创血流动力学监测临床应用的研究进展[J]. 现代生物医学进展,2016,14(16):2789-2792.
10. B.Bo Sramek,Ph.D.SYSTEMIC HEMODYNAMICS AND HEMODYNAMICS MANAGEMENT(4th Edition).
11.刘大为.血流动力学治疗: 从病因到过程的管理 [J/OL]. 中华重症医学电子杂志, 2016, 2 (2): 73-74.
12.沈洪.急危重症中无创血流动力学监护的临床应用[J].中国危重病急救医学,2003,15:190—192.
13.Shoemaker WC, Wo CC, Chien LC, et al. Evaluation of invasive and noninvasive hemodynamic monitoring in trauma patients[J]. J Trauma. 2006 Oct;61(4):844-53; discussion 853-4.
14.贾凤玉,孟建中,王素霞,等.Bioz.com数字化监测系统在血液净化中心的应用价值[J].中国血液净化,2011,10(11):599-601,633.
15.Teixeira JP, Zeidman A, Beaubien-Souligny W, et al. Proceedings of the 2022 UAB CRRT Academy: Non-Invasive Hemodynamic Monitoring to Guide Fluid Removal with CRRT and Proliferation of Extracorporeal Blood Purification Devices[J]. Blood Purif. 2023;52(11-12):857-879.
16.PRISM Investigators,Rowan KM,Angus DC,et al. Early,goal- directed therapy for septic shock-a patient-level meta-analysis[J].N Engl J Med,2017,376( 23) : 2223-2234.
17. 薛茫.维持性肾脏替代疗法对重症急性肾衰竭患者微炎症状态及肾功能影响的临床观察[J]. 临床肾脏病杂志,2017,17(12):744-747.
18.李晓利,王强,武若君,李彬,王亚真,张俊红.应用无创血流动力学监测仪评估肾移植患者手术前后血流动力学改变[J].中国组织工程研究与临床康复,2008,12(5):845-848.
19.郭安民,杜威宇,邝慧瑜,等. 肾移植前后左心功能对比分析及评价[J].中国现代医学杂志, 2004,14(17):110-111.
20.马彩娥,李平,吕发勤,等. 超声心动图评价肾移植前后心功能变化[J]. 中华超声影像学杂志, 2000, 9(9): 534-535.
Options
Outlines

/

[an error occurred while processing this directive]